Stripscan

Applies a bias voltage and performs a list of strip_measurements.

Type: stripscan

Configuration

  • name: (str) name of node.
  • strips: (str) range of strips to be measured. Default is an empty string.
  • enabled: (bool) enabled state. Default is true.
  • auto_disable: (bool) auto disable on success. Default is true.
  • parameters:
    • hv_channels: (list) list of high voltage channels. Default is [].
    • bias_voltage: (metric) bias voltage to be applied. Required.
    • bias_compliance: (metric) bias current compliance. Required.
    • waiting_time: (metric) waiting time in seconds between voltage change and readings. Default is 1 s.
  • strip_measurements: strip measurements.

Example configuration

- type: stripscan
  name: Stripscan
  strips: "1-1920"
  enabled: true
  auto_disable: false
  parameters:
    hv_channels: [A1, B1, C2]
    bias_voltage: -600 V
    bias_compliance: 25 uA
  strip_measurements: {}